Skip to content
Displai Displai Displai Knowledge Base Hoopla Help Center

How-to · Displai

Run multiple instances of DeepSight Toolkit on Windows

Run a separate DeepSight Toolkit instance for each camera on one Windows machine by adding a line per camera to start.bat.

KB-01918 steps Last verified

Use this procedure when you need to run multiple cameras on a single Windows machine with DeepSight Toolkit. Each camera requires its own instance of the Toolkit with a separate configuration directory.

  1. Open the DeepSight Toolkit installation directory on your Windows machine.

  2. Locate the start.bat file in the installation directory.

  3. Create a configuration directory for each camera instance you want to run (for example, C:\config1 and C:\config2).

  4. Open start.bat in a text editor.

  5. Add a line for each camera instance using this format:

    START DeepSight-Toolkit.exe --capture <camera_index> --camera-name <name> --deepsight-application <your_app_key> --config-path <config_directory>
  6. Replace the placeholders:

    • <camera_index>: Use 0 for the first camera, 1 for the second, and so on
    • <name>: Choose a descriptive name for the camera (for example, cam_01, cam_02)
    • <your_app_key>: Paste your Displai application key
    • <config_directory>: Enter the full path to the configuration directory you created (for example, C:\config1)
  7. Save the modified start.bat file.

  8. Run start.bat to launch all instances.

Each instance opens in its own window and connects to its assigned camera. Check that:

  • Each window shows a unique camera name you specified
  • Video feeds display from the correct cameras
  • No error messages appear in the command windows

Cameras don’t start or show errors about device access:

  • Verify each camera is connected and recognized by Windows
  • Check that no other application is using the cameras
  • Confirm each --capture index matches an available camera
  • Ensure camera indices are unique across all instances

Configuration conflicts or instances fail to launch:

  • Verify each --config-path points to a different directory
  • Check that all configuration directories exist before launching
  • Ensure your application key is valid and not expired

Need to identify which camera corresponds to which index:

  • Escalate to support for help mapping physical cameras to system indices

Still having trouble?

Text the 24/7 line or email support.